Facts About CMS Pulse Oximeters

By Madeline Pittman


CMS pulse oximeters are applicances applied in pulse oximetry. This sort of oximetry is a suitable technique for assessing levels of saturation of oxygen in human body because it is noninvasive. The device was invented around 1940s by a physician named Allan Millikan Glenn. The first appliance operated with 2 wavelengths and used to be placed on ears. The two wave-lengths were in form of green and red filters.

This original make was improved later by some physician named Wood in 1949. Wood integrated a pressure capsule for constricting blood out of an ear to get nil setting in a bid to get absolute O2 saturation level. The current models function on the same principals like the original one. The functioning principal was however hard to implement because of unstable light sources and/or photocells.

Oximetry itself was developed in the year 1972 at Nihon Kohden by 2 bioengineers, Takuo and Michio. These two bioengineers used the ratio between infrared and red light absorption of pulsating parts at measuring sites. A corporation called Biox did the first distribution of oximeter on large scale in the year 1981. By then, the appliance was chiefly utilized in operating rooms and corporations that manufactured it aligned most of their funds and advertising in this direction.

Oximetry is a crucial noninvasive technique of determining the amount of oxygen in human body. It utilizes a pair of small LEDS, light emitting diodes, which face some photodiode through a translucent portion of the body. Examples of such translucent parts are fingertips, earlobes, and toe tips. One LED is red whereas the other is infrared. The red LED is usually 660 nm while the infrared LED is 940, 910, or 905 nm.

The rate of absorption of the two wavelengths differs between the oxygenated and deoxygenated forms of oxygen within the body. This difference in absorption speed can be utilized to estimate the ratio between deoxygenated and oxygenated blood O2. The observed signal changes over some period with every heartbeat because arterial blood veins contract and expand with each heartbeat. The monitor is capable of ignoring other tissues or nail make-ups by monitoring the changing portion of the absorption spectrum only.

By observing the changing absorption section only, the blood oxygen monitor can display the percentage of arterial hemo-globin in oxyhemoglobin configuration. People without COPD with hypoxic drive conditions have a reading that lies between 99 and 95 percent. Patients with hypoxic drive conditions usually have values that lie between 94 and 88 percent. Usually figures of one hundred percent might suggest carbon monoxide poisoning.

An oximeter is usable in many environments and applications where oxygenation of a person is unstable. Among the major environments of use consist of ward and hospital settings, surgical rooms, cockpits in un-pressurized airplane s, recovery units, and intensive care units. The disadvantage of these equipment is that it can only measure the percentage of saturation of blood hemoglobin and not ventilation. Hence therefore, it is not a full evaluation of respiratory sufficiency.

CMS pulse oximeters are made in several varieties. Some are inexpensive costing a few dollars whereas others are very sophisticated and expensive. They may be purchased from any shop that stocks such pieces of equipment.